Energy-softening Nanofiltration (NF) Series
日期:2018-10-21 16:59 人气:
Energy-softening Nanofiltration (NF) Series
Introduction
The new coating technology, which applied in all nanofiltration membrane elements, has the advantages of efficient selectivity and filterability in separation processes without any chemical reaction, heating, phase transition, destroying biological natures or lower pressure than RO process. It has been applied in healthy drinking water and separation & concentration and purification process in food, medicine and biology more and more widely.
Specification and Main Performance of Membrane Elements
Model
|
Active Membrane Area ft2(m2)
|
Solution
|
Average Permeated Flow GPD(m3/d)
|
Stable Rejection Rate( %)
|
JNF-8040
|
400(37.2)
|
NaCl
|
7500(28.4)
|
40~60
|
MgSO4
|
6800(25.7)
|
>96
|
||
JNF-8040-HF
|
400(37.2)
|
NaCl
|
9500(35.9)
|
40~60
|
MgSO4
|
7500(28.4)
|
>96
|
||
JNF-4040
|
90(8.4)
|
NaCl
|
1500(5.7)
|
40~60
|
MgSO4
|
1350(5.1)
|
>96
|
||
JNF-4040-HF
|
90(8.4)
|
NaCl
|
1800(6.8)
|
40~60
|
MgSO4
|
1500(5.7)
|
>96
|
Testing Pressure ……………………………………………70 psi (0.5Mpa)
Temperature of Testing Solution……………………………25℃
Concentration of Testing Solution (NaCl)…………………2000ppm
Concentration of Testing Solution (MgSO4)………………2000ppm
pH Value of Testing Solution………………………………7.5
Recovery Rate of Single Membrane Element..……………15%
Operation Limits and Conditions
Max. Working Pressure……………………………….. 600psi(4.14Mpa)
Max. Feedwater Flow………………………………….. 75gpm(17m3/h) (8040)
16gpm(3.6m3/h) (4040)
Max. Feedwater Temperature…………………………45℃
Max. Feedwater SDI15…………………………………. 5
Residual Chlorine Concentration of Feedwater……….<0.1ppm
pH Range of Feedwater during Continuous Operation…3~10
PH Range of Feedwater during Chemical Cleaning…… 2~12
The Max. Pressure Drop of a Single Membrane Element .......15psi(0.1Mpa)